YRS03 Introduction:
YRS03 Reference White Noise Comb Spectrum Comparison Signal Source is a test instrument produced by York Company in the UK and distributed by EUTTEST in China, including the following three different configurations of test combinations:
- YRS03KIT01
- YRS03KIT02
- YRS Combination Kit
All three test kits include the YRS03 Master Noise Source, a multi-mode, broadband noise and comb spectrum noise generator source capable of generating a continuous noise output or a frequency comb in the 10 MHz-6 GHz range, with user-selectable step sizes. The noise generator is capable of looking at details across the entire spectral range, while the comb spectrum generator allows simultaneous viewing of the reference signal output and darkroom bottom noise verification, and checking the frequency accuracy of the device's measurements.
Technical parameters of the main noise source:
<<<<提醒:左右滑动表格>>>>output connector | 50Ω N |
size | 120mm*120mm*60mm. |
weight | 1kg |
electric power source | 4*1.5V rechargeable battery |
operating mode | Manual knob to select off or output mode |
white noise source pattern | |
Available frequency | 10MHz - 6 GHz Conducted Direct Outputs 30 MHz -- 6 GHz radiated output (MCN03 and MON03) |
temperature stability | <+/- 1 dB 9 kHz - 1 GHz, 15 °C - 30 °C <+/- 2.5 dB 9 kHz - 1 GHz, 5 °C - 40 °C |
York Domestic Agents | EUTTEST |
time stability | Less than 1 dB per year |
operating time | 6.5 hours |
Comb Comb Spectrum Generator Mode | |
Available frequency | 10MHz -6 GHz Conduction Output 30 MHz - 6 GHz Radiated Output (TLM02 and MON03) |
Step Selection | 5MHz, 10MHz, 20MHz, 40MHz |
temperature stability | <+/- 1 dB 9 kHz - 1 GHz, 15 °C - 30 °C <+/- 1.5 dB 9 kHz - 1 GHz, 5 °C - 40 °C |
frequency stability | <+/- 0.5 ppm, 5 °C -40 °C |
operating time | 14h |
Optional configuration models are available:
YRS Combination Kit Configuration Checklist:
<<<<提醒:左右滑动表格>>>>Comes standard with accessories: | YRS02 Reference comb spectrum noise comparison sourcereference source YRS03 Reference comb spectrum noise comparison sourcereference source TLM02 - 30 MHz to 300 MHz (optimum) 270 mm long top-loaded monopole antenna MON03 - 200 MHz to 1 GHz (optimum) 270 mm long monopole antenna MCN03 - 1 GHz to 6 GHz (optimum) monocone antenna LSA03 - LISN adapter with IEC 320 style connector CAL19 - 30 MHz to 6 GHz output powermeasured using a spectrum analyzer. all modes (YRS03 only)CAL16: 9kHz-1GHz conduction output data |
YRS03KIT01 Configuration list:
<<<<提醒:左右滑动表格>>>>Comes standard with accessories: | Reference Noise Source Host MCN03: Monopole Antenna 1GHz-6GHz CAL19: 30MHz-6GHz conduction output data |
YRS03KIT02 Configuration list:
<<<<提醒:左右滑动表格>>>>Standard Accessories | Reference Noise Source Host TLM02: 30MHz-300MHz Antenna MON03: 200MHz-1GHz Antenna MCN03: Monopole Antenna 1GHz-6GHz CAL19: 30MHz-6GHz conduction output data |
Other optional accessories:
Contact us for more information on configuration details.
- MON02: Telescopic rod antenna
- MON03: 200 MHz to 1 GHz (optimum) 270 mm monopole antenna
- TLM01 :200 MHz to 1 GHz (optimum) 100 mm top-loaded monopole antenna
- TLM02 : 30 MHz to 300 MHz (optimum) 270 mm top-loaded monopole antenna
- LSA03: Period verification of LISN adapter with IEC 320 style connector
- NIA01: Period verification ISN adapter with RJ11/RJ14/RJ25/RJ45 style connection
- CAL16: Conducted output power, Conducted output 9 kHz to 1 GHz, measured using a spectrum analyser. all modes.
- CAL17 Radiated field strength, radiated output 30 MHz to 1 GHz, measured at 3 m OR 10 m on an OATS using a spectrum analyser or receiver. all modes.
- CAL18 Radiated field strength, radiation output 30 MHz to 1 GHz, measured at 3 m in a FAR using a spectrum analyser or receiver. All modes.
- CAL19 Conducted output power, conducted output 30 MHz to 6 GHz, measured using a spectrum analyser. all modes.
- CAL21 Radiated field strength, radiated output 1 GHz to 6 GHz, measured at 3 m in a FAR using a spectrum analyser or receiver. Noise, 20 MHz and 40 MHz comb modes.

Direct output white noise spectrogram at DC-6GHz

Results of 1 GHz-6 GHz testing in an all-wave darkroom
For other frequency detailed test data and usage contact EUTTEST for more details.