R&S ENV216 Artificial Power Network LISN 9kHz-30MHz

Model: R&S ENV216

Min. order: 1 unit
Stock: 0
Delivery: 1-16 weeks

Standards:
Industry: /

Warranty: Original Import ; New Products ; Authorized Sales
Training: On-site training; Telephone; Email
Logistics: Shenzhen to National
Payment: Online banking

Product Price:

Product Description:

The R&S ENV216 2-wire V-shaped artificial power network meets the requirements of CISPR 16-1-2 and EN 55016-1-2 for V-shaped networks with an analog impedance of (50 μH + 5 Ω ) || 50 Ω over the frequency range of 9 kHz to 30 MHz, and meets the relevant requirements of ANSI C63.4 for the frequency range of 150 kHz to 30 MHz. 150 kHz to 30 MHz. negative connector connection EUTs are available with ground protection contacts. several models of the ENV216 are available to comply with country-specific power connector systems. the ENV216 is designed for CE interference voltage measurements on single-phase EUTs.

Product Features:

  • 9 kHz to 30 MHz frequency range
  • Power handling capacity up to 16 A, constant current (varies by country)
  • Analog Impedance (50 μH + 5 Ω) || 50 Ω per CISPR 16-1-2 Amd. 2:2006
  • V-networks compliant with CISPR, EN, VDE, ANSI, FCC Part 15 and MIL-STD-461D, E and F
  • Calibrated according to CISPR 16-1-2

Product Advantage:

  • Empty core design as well as analog hand
  • The R&S ENV216 2-wire V-network is based on an air-core inductor and contains an analog hand.
  • Selectable switchable 150 kHz high pass filter
  • To prevent the measurement receiver from being overloaded by high levels of the low-frequency spectrum, a 150 kHz high-pass filter can be inserted.
  • Built-in 10 dB attenuator
  • To ensure standard impedance (regardless of receiver input attenuation), the R&S ENV216 is equipped with a 10 dB attenuator.
  • Built-in pulse limiter (can be turned off)
  • A built-in pulse limiter (which can be turned off) protects the receiver input.
  • Remote Control TTL Levels (with Rohde & Schwarz)EMI Measurement Receiver(Compatible)
  • The TTL control inputs are driven via a controller as well as a Rohde & Schwarz measurement receiver and can be used for remote control (phase selection and activation of high-pass filters) in automated test systems. An optocoupler protects against external interference.

R&S ENV216 Technical data.

<<<<提醒:左右滑动表格>>>>
Frequency range 9 kHz to 30 MHz
Analog ImpedancePhase and amplitude(50µH + 5Ω) || 50Ω
error limit±20% (amplitude), ±11.5° (phase), compliant with CISPR 16-1-2
isolation 1)9 kHz to 50 kHz>0 dB to 40 dB (linear increase in logarithm of frequency)
 50 kHz to 30 MHz>40 dB
Test path to the EUT euttest
AC supply voltageIf the EUT is operated with AC voltages up to 90 V and DC voltages up to 50 V, the logic circuitry must be powered through the external plug-in power supply that comes standard.0 V to 240 V AC + 10%
AC power frequency50 Hz to 60 Hz ± 5%
dc voltage0 V to 50 VDC
Maximum allowable continuous currentVaries by country/region
Model 1216 A
Model 1313 A
Model 1416 A
Model 1510 A
Model 1615 A
Test path to the measurement receiver
Maximum Allowable EUT RF Interference Power1 W
High-pass filterIntegrated, Selectable Switch150 kHz
Voltage dividing factor between EUT and measurement receiver portsBuilt-in attenuator with calibration data (using V-network)10 dB
Response threshold for built-in pulse limitercloseable140 dB (µV)
terminal (electrical engineering)
AC power inputVaries by country/regionPlug with grounding contact and 1.8 m cable
AC supply voltage input for EUTVaries by country/regionReceptacle with grounding contact
RF outputNegative, 50Ω
Remote Control Input25 Contacts, D-Sub, Negative
Analog hand input4 mm Fitting, euttest, negative, with knurled fixture
reference groundGround rod with three M4 threads
groundingM6 Threaded Pins
External power connectorLocated on the rear panel and powered by the supplied plug-in power supplyDC hollow connectors Ø5.5 mm, 2.1 mm, 10 V to 18 VDC, 250 mA
Common data
Operating Temperature Range+5°C to +45°C
Storage temperature range-40°C to +70°C
sizeW × H × D219 mm × 147 mm × 350 mm
(8.6 in × 5.8 in × 13.8 in)
weight5.5 kg (12.1 lb)
electrical safetyFollow the instructions in the manualConforms to EN 61010
EMCConforms to IEC/EN 61326
radiateCategory B, in line with the requirements of the residential environment
anti-interferenceMeets the requirements of industrial environments
<<<<提醒:左右滑动表格>>>>

 

Service

Our company sells all the instrumentation equipment products provide after-sales personnel door-to-door training or telephone, e-mail, microblogging and other ways of installation and training services.

We are committed to supplying equipment that is brand new and manufactured by the original manufacturers at home and abroad.

After-sales of the product is carried out by the after-sales policy provided by the original equipment manufacturer.

Purchase

The EUTTEST website does not sell any products online and is only used to display information about the products that our company represents and sells or researches in-house.

The prices shown are for display purposes only, please contact our sales staff to get the real-time quotation information of the required instruments and equipment products;

When you confirm your purchase, we will contact you to sign a purchase and sales contract.

Our company only deals with companies and provides formal Chinese VAT special invoices.

Sales call:134 2515 8926

Sales mailbox:sales@euttest.com

Company Wechat: euttest

202 views

DISCLAIMER: Reproduction and redistribution by anyone without written permission from EUTTEST is prohibited.

If you like our products, please press Ctrl + D shortcut to favorite this product.