R&S BBL200 Liquid Cooled High Field Strength Power Amplifier 9kHz-225MHz

Model: R&S BBL200

Min. order: 1 unit
Stock: 0
Delivery: 1-16 weeks

Standards: /
Industry: /

Warranty: Original Import ; New Products ; Authorized Sales
Training: On-site training; Telephone; Email
Logistics: Shenzhen to National
Payment: Online banking

Product Price:

Product Description:

The BBL200 is a liquid-cooled broadband amplifier for applications requiring high RF power, manufactured by R&S and distributed by EUTTEST.The R&S BBL200 broadband amplifier series produces 3kW, 5kW, and 10kW of power in the frequency range of 9kHz to 225MHz. The amplifiers have a liquid-cooled solid-state design, are highly ruggedized and are highly efficient and noise-free. Accurate monitoring of all runtime parameters ensures maximum robustness and reliability.

offeringsFeatures:

  • Frequency range from 9 kHz to 225 MHz
  • 3000W, 5000W and 10000W output power
  • 100% Mismatch Tolerance
  • Specially designed for continuous operation even under mismatch conditions
  • Liquid-cooled, compact and silent
  • Suitable for amplitude, frequency, phase and pulse modulation
  • Global service network and global spare parts availability
  • Class A amplifier
  • The R&S BBL200 covers open source software packages. Copies of the respective licenses are included in the "Open Source Confirmation", which can be found in the downloads/firmware section of this web page.

offeringsAdvantage:

  • One of the most advanced high power amplifiers on the market
    • Sophisticated RF design
    • Liquid-cooled design, small and compact
    • mass produce
  • Reliability due to high availability
    • Deep expertise in amplifier development
    • Cost advantages due to short downtime
    • Reliable performance even under mismatch conditions
  • Flexible control and operation
    • manual operation
    • Local and remote operation via web browser and PC
    • Ethernet or GPIB remote control
    • integrate intoR&S EMC32 EMC Measurement Software
    • Two different interlocks for high security levels
  • Easy to repair and quick maintenance
    • EUTTEST's outstanding service concept
    • Extended warranty designed to maximize investment protection
    • From pre-sales support to after-sales service, Shenzhen offers services.

R&S BBL200 Sequence Power Amplifier Optional Models:

<<<<提醒:左右滑动表格>>>>
R&S BBL200 Single Band Power Amplifier
Frequency band (9kHz to 225MHz)
3000W, Liquid Cooled‑, 31HU Rack ModelR&S®BBL200BBL200-A3000
5000W, Liquid Cooled‑, 42HU Rack ModelR&S®BBL200BBL200-A5000
10,000W, liquid-cooled‑, 2x42HU rack modelsR&S®BBL200BBL200-A10000
Included accessories: EUTTEST service guide, rack power cord, printed and CD manuals, test report, indoor heat exchanger, 2 x 20m cooling hoses and filling pump.
<<<<提醒:左右滑动表格>>>>
  • R&S®BBA-B101:
    • GPIB Remote Control
  • R&S®BBA-B132:
    • DC blocking input protection (N)
  • R&S®BBL-B140:
    • RF Forward/RF Reflective Sampling Port (Type N)
  • Bottom rear panel connector for 3000W and 5000W models
  • R&S®BBL-B140:
    • RF Forward/RF Reflective Sampling Port (Type N)
  • Bottom rear panel connector for 10000W models, top rack connector for all models
  • R&S®BBL-B141:
    • Detect Positive/Detect Reflective Sampling Port (N-Type)
  • R&S®BBL-B160:
    • Transparent I/O
  • R&S®ZR1-RW01:
    • Rack rollers

R&S BBL200 Serial High Field Strength Power Amplifier Technical Data:

<<<<提醒:左右滑动表格>>>>
RF data
Frequency range9kHz to 225MHz asynchronous
Nominal output load50Ω
nominal power3000W (64.8dBm), 5000W
(67dBm),
10000W (70dBm)
modulation capabilityAM, FM, φM, PM
Nominal Power Gain3000W model68.2dB
5000W model70.4dB
10000W Model73.4dB
Gain Flatness±3.0dB
Gain adjustment range>15dB
harmonic (wave with frequency an integer multiple of the fundamental)3000W model
Between 9kHz and 110MHzeuttest at 3000W
Between 110MHz and 225MHzeuttest at 2800W
<-20dBc
5000W model
9kHz to 110MHz at 5000W
110MHz to 225MHz at 3500W
<-20dBc
10000W Model
9kHz to 110MHz at 10,000W
110MHz to 225MHz at 8000W
<-20dBc
strayCarrier bias >100kHz-80dBc (nominal), -70dBc max.
coefficient of noise9kHz to 50MHz<16.0 dB (nominal)
50MHz to 225MHz<9.0 dB (nominal)
Nominal Input Impedance50Ω
Input level corresponding to nominal output power-3.4dBm
Input VSWRto 50ΩMaximum 2:1
Maximum Input Levela radio frequency+5dBm
direct current (D.C.)0V
Nominal Output Impedance50Ω
Positive Output PowerAt VSWR<6:1Sustained, no turnaround
At VSWR>6:1Continuous, progressive foldback is an approximation of the output power of the 50%, depending on the phase and amplitude of the mismatch
Output Adaptation Protection, VSWR100%, non-destructive
RF sampling as well as detected RF sampling signals
RF Sampling Signal Coupling FactorRF forward and reflection sampling port, euttest optionalApprox. 70dB (see test report for details)
Sampled signal level detectedForward and reflective sampling ports for detection, euttest optional0.1V to 3.0V DC
Mechanical specifications of the amplifier system
sizeRack mounting, W×H×D, with handle, column and lifting support
3000W model600mm×1570mm×1150mm
(23.62in x 61.81in x 45.28in)
5000W model600mm×2050mm×1150mm
(23.62in x 80.71in x 45.28in)
10000W Model1200mm×2050mm×1150mm
(47.24in x 80.71in x 45.28in)
Mechanical specifications for heat exchangers
sizeW×H×D, including handle and column
3000W model1241mm×558mm×400mm
(48.86in x 21.97in x 15.75in)
5000W model1125mm×925mm×600mm
(44.29in x 36.42in x 23.62in)
10000W Model2400mm×1150mm×600mm
(94.49in x 45.27in x 23.62in)
connector
Connection plate located at the bottom of the top cover or rear panel of the frameRF Input PortN Female Connectors
Sampling port for RF or detected RFN Female Connectors
EthernetRJ-45
interlockWAGOX-COM®, 7‑pin, female connector
amplifier statusWAGOX-COM®, 7‑pin, female connector
Transparent I/O, optional2×WAGOX-COM®, 7‑pin, female connector
RF output portRear Plate, Bottom15/8″ EIA Female Connector
power supply (of an appliance etc)Rear Plate, Bottom
3000W model5×4mm2power cable (of an appliance etc)
5000W model, 10000W model5×35mm2power cable (of an appliance etc)
Coolant supplyRack top cover, rear panel or rack shelf
Electrical specifications for amplifier systems
Nominal operating voltage range380V to 415V AC ±10%, three-phase (with N-type connector).
50Hz to 60Hz ±6%
208V to 240V AC ±10%, three-phase.
50Hz to 60Hz ±6%
nominal current3000W model, 230V, according to phase<20.5A
5000W model, 230V, according to phase<35A
10000W model, 230V, according to phase<72A
nominal power3000W Model, RFcw= 3000W (RMS), VSWR = 1<14.2kVA
5000W Model, RFcw= 5000W (RMS), VSWR = 1<24kVA
Model 10000W, RFcw= 10000W (RMS), VSWR = 1<50kVA
Electrical specifications for heat exchangers
Nominal operating voltage range230V AC ±10%, single phase.
50Hz to 60Hz ±6%
Current (at 230V)3000W model<1.5A
5000W model<3.5A
10000W Model<13A
power wastage3000W model<350VA
5000W model<810VA
10000W Model<3000VA
Cooling specifications
cooling circuitClosed cooling system with automatic pressure equalization
coolant39%v/v Frost Resistant®N
(based on monoethylene glycol, water and anticorrosion additives)
heat exchangersquantitative (science)
3000W modelMaximum 9.5kW
5000W modelMaximum 15.7kW
10000W ModelMaximum 41kW
air flow
3000W model6200m3/h
5000W model5145m3/h
10000W Model20100m3/h
Installation typeIndoor or outdoor, floor installation
between the amplifier system and the heat exchanger
Recommended Distance
Tube lengthMaximum 2×20m
altitude differenceMaximum 20m
Cooling hosesexternal diameter (including thickness of the wall)
3000W model2×40mm (2×1.57in)
5000W model, 10000W model2×51mm(2×2.0in)
bending radius280mm(11in)
graphical user interface (GUI)
local monitor200 x 48 pixels, monochrome
WebGUIVia EthernetRJ-45, 10/100Mbit/s, auto-negotiation, half/full duplex
remote control
Ethernet cableRJ-45, 10/100Mbit/s, auto-negotiation, half/full duplex,EUTTEST imported cable
environmental conditions
Temperature loadOperating Temperature Range0°C to +40°C
Storage temperature range-20°C to +70°C
athlete's footUp to +40°C at 95% relative humidity.
uncompensated
high degreeOperating heightUp to 2000m
Storage heightUp to 4600m
safeguard
Load VSWRfinite
interlock1 device interlock, 1 configurable interlock
Input protection against bias voltageselectableDC blocking level ≤ 50V DC
Transient Voltage CompatibilityClass II according to IEC 60364-4-443
Internal fuse exchange capacity<10kA
thermal overloadShutdown on thermal overload (+50°C ambient temperature)
pressure overloadPressure reducing valve, 5 bar
module switchingself-closing valve
<<<<提醒:左右滑动表格>>>>

All specified parameters are valid at an ambient temperature of +25°C, an input impedance of 50Ω, and an output impedance of 50Ω.

 

Service

Our company sells all the instrumentation equipment products provide after-sales personnel door-to-door training or telephone, e-mail, microblogging and other ways of installation and training services.

We are committed to supplying equipment that is brand new and manufactured by the original manufacturers at home and abroad.

After-sales of the product is carried out by the after-sales policy provided by the original equipment manufacturer.

Purchase

The EUTTEST website does not sell any products online and is only used to display information about the products that our company represents and sells or researches in-house.

The prices shown are for display purposes only, please contact our sales staff to get the real-time quotation information of the required instruments and equipment products;

When you confirm your purchase, we will contact you to sign a purchase and sales contract.

Our company only deals with companies and provides formal Chinese VAT special invoices.

Sales call:134 2515 8926

Sales mailbox:sales@euttest.com

Company Wechat: euttest

159 views

DISCLAIMER: Reproduction and redistribution by anyone without written permission from EUTTEST is prohibited.

If you like our products, please press Ctrl + D shortcut to favorite this product.