Product Description:
The NSG 3040A is a Combined Wave Generator manufactured by TESEQ (Switzerland) and distributed by EUTTEST (Shenzhen). The NSG 3040 has been discontinued and has been replaced by the new NSG 3040A. The system is designed to meet the EMC test requirements for CE marking tests, which typically include Combined Surge, Electrical Fast Transient (EFT) pulses and Power Quality Tests (PQT). Extensive expansion capabilities allow the system to be configured for a wider range of applications.
It is an easy-to-use, multifunctional generator that simulates electromagnetic interference effects for immunity testing in compliance with international, national and manufacturer's standards, including the latest IEC/EN standards.The NSG 3040A, with its innovative modular design, is a multifunctional system that can be configured for basic test requirements and expanded to meet the needs of complex test labs. Extensive expansion capabilities allow the system to be configured for a wider range of applications.
Mainframe optional model:
NSG3040A is available in several sub-models, please contact EUTTEST for more information on detailed specifications.
NSG3040A-IEC
Multi-function generator for EFT / Pulse Group (4.8 kV), Surge Combined Wave (4.8 kV), Voltage Interruptions and Variability as well as IF / Pulsed Magnetic Field testing. The choice of pulse module depends on your testing needs.
NSG3040A-EFT-CWS
Multi-function generator for EFT / burst (4.8 kV) and surge combination waves (4.8 kV).
NSG3040A-CWS
Multi-function generator for surge combination waves (4.8 kV).
NSG3040A-DDV
Multi-function generator for voltage interruptions and variations as well as industrial frequency/pulsed magnetic field testing.
NSG3040A-EFT
Multi-function generator for EFT / Pulse Swarm (4.8 kV).
Technical parameters:
Combined wave pulse 1, 2/50-8/20μs (mixed surge pulse)
Pulse according to IEC / EN 61000-4-5
<<<<提醒:左右滑动表格>>>>parameters | (be) worth |
Pulse voltage (open circuit) | ±200 V to 4.8 kV (in 1 V steps) |
Pulse current (short circuit) | ±100 A to 2.4 kA |
impedance | 2/12 ohm |
polarities | Positive/Negative/Alternating |
Pulse Repetition | 10 seconds up to 9'999 seconds (in 1 second steps) |
Testing time | 1 to 99'999 pulses, continuous |
phase synchronization | Asynchronous, synchronous 0 to 359º (in 1º steps) |
be coupled (with sth) | IEC (external/internal) |
Burst (EFT) 5/50 ns
Pulse according to IEC / EN 61000-4-4
<<<<提醒:左右滑动表格>>>>parameters | (be) worth |
pulse amplitude | ±200 V to 4.8 kV (in 1 V steps) - open circuit ±100 V to 2.4 kV (50Ω matched system) |
burst frequency | 100 Hz to 1000 kHz |
polarities | Positive/Negative/Alternating |
repetition time | 10 ms to 9'999 s |
timing of an outbreak | 10μs to 9'999 s, single pulse |
Testing time | 1 s to 9'999 s, 1 min to 1600 min, endless |
phase synchronization | Asynchronous, synchronous 0 to 359º (in 1º steps) |
be coupled (with sth) | External Internal |
Sudden drops, interruptions and changes
Complies with IEC / EN 61000-4-11, IEC / EN 61000-4-29.
<<<<提醒:左右滑动表格>>>>parameters | (be) worth |
Inclination, interruptions and changes | 0 V, 0% from EUT voltage input |
Uvar with optional autotransformer | Depends on model (VAR 3005A) |
Uvar with step transformer | 0, 40, 70, 80% (INA 650x) |
Peak surge current capability | > 500 A (at 230 V) |
cutoff time | 1 to 5μs (100Ω load) |
Time of Event (T-Event) | 20 µs to 9'999 s, 0.5 to 9'999 cycles |
repetition time | 10 ms to 9'999 s, 1 to 9'999 s |
Testing time | 1 to 99,999 events, continuous |
phase synchronization | Asynchronous, synchronous 0 to 359º (in 1º steps) |
Deviation test (VAR 3005A only)
Conforms to IEC / EN 61000-4-11
<<<<提醒:左右滑动表格>>>>parameters | (be) worth |
Uvar with optional autotransformer | Up to approx. 265 V (in 1 V steps) or up to 115% Uin (in 1% steps) |
Reduction time Td | 1 ms to 9.999 s, 0.5 to 9999 cycles, sudden |
UTime for lowering the voltage Ts | 1 ms to 9.999 s, 0.5 to 9999 cycles |
Increase time Ti | 1 ms to 9.999 s, 0.5 to 9999 cycles |
repetition time | 1 to 5μs (100Ω load) |
major event | 1 to 99'999 |
Pulsed magnetic fields in combination with 702A
Conforms to IEC / EN 61000-4-9
<<<<提醒:左右滑动表格>>>>parameters | (be) worth |
realm | 100 to 1200 A/m |
polarities | Positive/Negative/Alternating |
repetition time | 10 s to 9999 s (in 1 s steps) |
impedance | 2Ω |
Coil/impedance factor | 0.01 to 100.00 |
Testing time | 1 to 9'999 pulses, endless |
phase synchronization | Asynchronous, synchronous 0 to 359º (in 1º steps) |
Power magnetic fields in combination with MFT 30 or MFO 6501 and MFC 30 and MFC 300
Conforms to IEC / EN 61000-4-8
<<<<提醒:左右滑动表格>>>>parameters | (be) worth |
realm | 1 to max. 40 A/m |
frequency | 50 or 60 Hz |
coil factor | 0.01 to 100 |
Testing time | 1 s to 99'999 s, endless |
Optional accessories:
Description of related accessories
CDN 117/CDN 118
CDN 117 Data Line Coupling/Decoupling Networks
CDN 118 Telecom Line Coupling/Decoupling Networks
CDN 3425
EFT Pulse Group Coupling Clip
CDN HSS-2
Coupling decoupling network for unshielded symmetric high-speed communication lines
CAS 3025
EFT Pulse Group Pulse Voltage Calibration Verification Kit
INA 701/702/703
Magnetic field coil
INA 6501
Manual Step Transformer
INA 6502
Auto step transformer
MD 210
High Voltage Differential Probe Series
MD 300
Surge Pulse Current Probe Kit