FCC Current Probe Current Injection Probe Current Monitoring Probe Current Clamp Current Clamp Product Catalog and Quotation

Model: FCC Current Probe
Brand: FCC

Min. order: 1 unit
Stock: 0
Delivery: 1-16 weeks

Industry: /

Warranty: Original Import ; New Products ; Authorized Sales
Training: On-site training; Telephone; Email
Logistics: Shenzhen to National
Payment: Online banking

Product Price:

summary

FCC current probe is produced by the U.S. FCC and authorized by the domestic Shenzhen EUTTEST agent sales of products for CE conducted emission and BCI current injection and current monitoring test.FCC is the United States Fischer Custom Communications, Inc. short for the U.S. FCC is the United States FCC mainly produces DC-6GHz RF current probe, the United States FCC. FCC Inc. is not the U.S. FCC Standards Committee, which are two different organizations. FCC produces current injection and monitoring probes, TEM cells for IC testing, coupling and decoupling networks CDN, ISNs compliant with CISPR22/32, single-phase and three-phase LISNs, and other equipment.

Classification:

Current probes, also called current clamps, are current probes used in EMC measurements and tests. The current probe principle was developed on the theoretical basis of Faraday's law and Lenz's law.

FCC USA has two types of current probes and injection clamps, including:


BCI High-Current-Injection Probe: Injecting Interference into Cables

  • Calibration Fixture - Injection Probe

 EMI-Monitoring Current Probe: Measuring Interference on Cables

  • Calibration Fixture-Monitoring Probe

Both are simply clamped to the cable under test to inject high frequency current interference signals or test for high frequency current interference on the EUT to be measured.

Principle:

  • ①, when injecting high-frequency current, the current enters into the PCB through the conductor, capacitive coupling and other effects to affect the normal function of the PCB, which is a limit point in the EMC test.
  • ②, when clamping the EUT cable for testing, the high-frequency current conducted by the PCB on the cable is coupled to the monitoring current probe, and then transmitted via the coaxial cable to the EMI test receiver to display the current spectrum, in order to assess whether the high-frequency interference released by the EUT during normal operation is within the limits required by the standard.

Don't know how to use? Click here to view - " How to Use Injection Current Probe and Monitoring Current Probe

Testable Standards.

FCC USA's products meet the following standards

  • IEC/EN 61000-4-6
  • MIL-STD-461/462
  • EN55022/CISPR 22/CISPR32 standards
  • Pulse Generator for MIL-STD- 188-125
  • EMP test systems are used to verify the ability of sensitive electronic equipment to withstand EMP, high power microwaves and other electromagnetic threats.
  • Transient protection devices:Transient protection devices or surge suppressors are used to protect sensitive electronic communications equipment from lightning, EMP, high power microwaves and other electromagnetic threats. Surge suppressor models are available for frequencies above 3 GHz.
  • Data Line Suppressor:Available for 10/100/1000 Base T systems.

EutTest Services:

Our company is the agent of the U.S. FCC about the current probe in civil electronics (such as CISPR32), aerospace (DO160\MIL-STD-461), vehicles and ships (MIL-STD-461), automotive electronics (CISPR25) and other fields, to provide a complete range of parameters of the transmission impedance, easy to use in test software to realize automated testing, and the other. EutTest provides after-sales installation and training services for all current probes sold.

US FCC Current Injection Probes BCI-Catalog

FCC Current Injection Probe Equipment List and Technical Parameters

FCC Current Injection Probe

FCC Current Injection Probe

FCC current injection probes comply with the following standards: DO-160 E/F/G: Airborne Equipment Environmental Conditions and Test Procedures, IEC 61000-4-6: Conducted Nuisance Immunity Tests for RF Field Induced, MIL-STD 461 / GJB151B / GJB151A,GJB152B: Military EMC, ISO11452-4: Automotive Electronics. BCI high current injection open/closed loop test.

Use CTRL+F to search for the models you need and provide them to us for a quote.
Click on the model number to view detailed product technical parameters. Please contact EUTTEST for unlinked models.

<<<<提醒:左右滑动表格>>>>
Product modelAvailable frequencyrated

power (output)

(CW)

Insertion Loss - TypicalInner ring diameter

(mm)

Outer ring diameter

(mm)

high degree

mm

Calibration Fixture
F-170701-1008-110MHz - 400MHz1000<8dB / 10MHz - 400MHz4012770FCC-BCICF-1
F-170501-1008-110MHz - 400MHz2500<7dB / 10MHz - 400MHz40127134F-170421-1008-1
F-161012-1008-110kHz - 10MHz2500<7dB / 200kHz - 10MHz54 x 108203 x 305241F-161012-1008-2
F-080915-1008-13GHz - 4GHz100<8dB / 3.2GHz - 3.9GHz325310F-080915-1008-2
F-120501-1008-11kHz - 10MHz1000<9dB / 500kHz - 10MHz40 x 91152 x 286191F-120501-1008-2
F-120-7B10kHz - 400MHz125<10dB / 1MHz - 400MHz6514254FCC-BCICF-3
F-080409-1008-12.0 GHz - 3GHz100<9dB / 2GHz - 3.0GHz327119F-080409-1008-2
F-120-8F10kHz - 400MHz250<5dB / 500kHz - 200MHz40127134*, f-170421-1008-1, fcc-bcicf-4
F-150-2800MHz - 2.1GHz250<9dB / 800MHz - 2.1 GHz409838FCC-BCICF-150-2
F-140-HV100kHz - 400MHz5kV

Peak Pulse

<7dB / 2MHz - 300MHz4012770FCC-BCICF-1-HV
F-080728-1008-1500MHz - 1GHz250<7dB/500MHz - 800MHz6514254F-080728-1008-2
F-150-12.3GHz - 7.0GHz100<9dB/2.3GHz - 7GHz123313FCC-BCICF-150-1
F-070601-1008-1400MHz - 1GHz250<7dB/450MHz - 1GHz4012770F-070601-1008-2
F-150800MHz - 2.1GHz250<7dB/950MHz - 2.0GHz329838FCC-BCICF-150
F-130A-11MHz - 400MHz100<7dB/3MHz - 350MHz4012770FCC-BCICF-1
F-130-31MHz - 400MHz100<7dB/3MHz - 200MHz6514254FCC-BCICF-3
F-1401MHz - 1GHz1004012770FCC-BCICF-2
F-120-9A10kHz - 230MHz125<8dB/150kHz - 100MHz40127134fcc-bcicf-6-150
F-120-6A10kHz - 400MHz100<7dB/700kHz - 200MHz4012770FCC-BCICF-1
F-120-910kHz - 230MHz100<11dB/150kHz - 230MHz4012770FCC-BCICF-1
F-120-810kHz - 400MHz200<7dB/800kHz - 300MHz40127134*, f-170421-1008-1, fcc-bcicf-4
F-120-510kHz - 100MHz100<10dB/500kHz - 1MHz6514253FCC-BCICF-3
F-191011-1008-110kHz - 500MHz200<10dB/150kHz - 500MHz5013770F-191011-1008-2
<<<<提醒:左右滑动表格>>>>

*:Selected according to test criteria, contact us for more information

New for 2021: Injection Probe F-191011-1008-1 with Current Monitoring Probe F-180419-1005-1.

2.2, FCC current injection probe calibration fixture Metrology calibration fixture

Calibration Fixture for FCC Current Probes

Calibration Fixture

FCC current injection probe and current monitoring probe calibration fixtures meet the requirements of the following standards and can be supplied directly to metrology institutes for annual metrology services. Contact EUTTEST for more information.

DO-160 C,D,E,F,G, MIL-STD 461 C,D,E,F, J-1113-4, ISO11452-4;

<<<<提醒:左右滑动表格>>>>
Calibration Fixture ModelCurrent injection probe models that can be matched
F-040128-1008-2AF-040128-1008-1A
F-070601-1008-2F-070601-1008-1
F-080409-1008-2F-080409-1008-1
F-080728-1008-2F-080728-1008-1
F-080915-1008-2F-080915-1008-1
F-120501-1008-2F-120501-1008-1
F-161012-1008-2F-161012-1008-1
F-170421-1008-1f-120-8, f-120-8f, f-170501-1008-1
FCC-BCICF-1f-120-1, f-120-2, f-120-3, f-120-3b, f-120-6a.

f-120-9, f-120-9b, f-130-1, f-130a, f-130a-1

FCC-BCICF-1-HVF-140-HV
FCC-BCICF-150F-150
FCC-BCICF-150-1F-150-1
FCC-BCICF-150-2F-150-2
FCC-BCICF-2F-140A-1
FCC-BCICF-2-1F-070601-1008-1
FCC-BCICF-3f-120-5, f-130-3
FCC-BCICF-4f-120-3a, f-120-3a-1, f-120-8, f-120-8f, f-120-8g, f-120-9a, f-130-2
FCC-BCICF-4-HVF-120-8-HV
fcc-bcicf-6-150F-120-9A
<<<<提醒:左右滑动表格>>>>

 

US FCC Current Monitoring Probes EMI-Catalog

FCC Current Monitoring Probes Equipment List and Technical Data Monitor Probes:

FCC current monitoring probes comply with the following standards. Current monitoring probes can only measure small signals, do not use them for large signal testing!

CISPR 22/32, CISPR 25 Current Method CE Test Transmit to Transmit, DO-160 C,D,E,F, IEC 61000-4-6, MIL-STD 461 C,D,E,F, J-1113-2, J-1113-4, ISO11452-4 High Current Injection Monitoring Probe, Required for Closed Loop Method Testing, 1752-2.

FCC Current Monitoring Probe

FCC Current Monitoring Probe

Use CTRL+F to search for the models you need and provide them to us for a quote.
Click on the model number to view detailed product technical parameters. Please contact EUTTEST for unlinked models.

 

<<<<提醒:左右滑动表格>>>>
Model numberAvailable frequency
A
inner ring
calibre
B
outer ring
calibre
C
high degree
(mm)
ZTΩDBΩconnector
greatest
Current <400Hz
RF
(CW)
impulse
peak value
Calibration Fixture
F-1010Hz -2MHz3294640.25-12N350100100fcc-mpcf-1-32/94/64
F-10-110Hz -2MHz3294640.03-30N5025500fcc-mpcf-1-32/94/64
F-10A10Hz - 2MHz67142530.25-12N350100100fcc-mpcf-1-32/94/64
F-10A-110Hz - 2MHz67142530.03-30N5025500fcc-mpcf-1-32/94/64
F-1210Hz - 3MHz3294640.32-10N350100100NULL
F-1410 Hz - 500 kHz3294640.12-18N40050500fcc-mpcf-1-32/94/64
F-14-110 Hz - 500 kHz3294640.02-33N40025500fcc-mpcf-1-32/94/65
F-14-C10 Hz - 2 MHz3298380.03-30N5010100fcc-mpcf-2-32-40/98/38
F-14A10 Hz - 500 kHz67142530.12-18.5N40050500fcc-mpcf-2-67/142/53
F-14A-110 Hz - 500 kHz67142530.03-30.5N40025500fcc-mpcf-2-67/142/54
F-1610 Hz - 70 MHz329464412N40050300fcc-mpcf-1-32/94/64
F-16-110 Hz - 70 MHz3294640.5-6N4003300fcc-mpcf-1-32/94/64
F-16A10 Hz - 70 MHz6714253412N5050300fcc-mpcf-2-67/142/53
F-16A-110 Hz - 70 MHz67142530.5-6N4003300fcc-mpcf-2-67/142/53
F-16M100 Hz - 50 MHz3298380.5-6N400250fcc-mpcf-2-67/142/54
F-170302-1005-110Hz - 50MHz4080190-60N2022000fcc-mpcf-3-32-40/71/19
F-170308-1005-110Hz - 50MHz67142530.7-3N502100fcc-mpcf-2/67/142/53
F-170317-1005-1100kHz - 300MHz305394513.511N10002100fcc-mpcf-1-127/197/41
F-170329-1005-110kHz - 30MHz67142531.43N10002100fcc-mpcf-2/67/142/53
F-170705-1005-1100kHz - 30MHz671425326N7502100fcc-mpcf-2/67/142/53
F-170710-1005-110kHz - 400MHz3271190.35-9N502100fcc-mpcf-3-32/71/19
F-170804-1005-110kHz - 400MHz6510419514N1502100fcc-mpcf-2-67/142/53
F-180419-1005-110kHz - 500MHz******************F-191011-1008-2
F-180907-1005-110kHz - 108MHz127197415.615N500100100fcc-mpcf-1-127/197/41
F-180907-1005-210kHz - 108MHz127197411ØN5001010fcc-mpcf-1-127/197/41
F-180907-1005-310Hz - 1MHz127147410.1-20N100010100fcc-mpcf-1-127/197/41
F-2000-12mm10MHz - 3GHz1337131624SMA1001050FCC-MPCF-2K Rev B
F-2000-32mm-110MHz - 2.1GHz3271191822N3503100F-050315-1005-1
F-2000-32mm-210MHz - 3GHz3271191822N3503100F-050315-1005-2
F-2000-40mm-110MHz - 2.1GHz4080191825N3502100FCC-MPCF-F-2000-40mm
F-33-110 kHz - 250 MHz3271196.316BNC*1001050fcc-mpcf-3-32/71/19
F-33-21 kHz - 250 MHz3271191ØBNC*100250fcc-mpcf-3-32/71/19
F-33-31 kHz - 200 MHz327119412BNC*1001050fcc-mpcf-3-32/71/19
F-33-510 kHz - 140 MHz2051131.32.3SMA251050fcc-mpcf-3-32/71/19
F-33-61 kHz - 200 MHz319190.8-2SMA5110fcc-mpcf-3-32/71/19
F-35100 Hz - 100 MHz32983810N2003100fcc-mpcf-2-32-40/98/38
F-35A100 Hz - 100 MHz32983810N2003100fcc-mpcf-2-32-40/98/38
F-35-110 kHz - 100 MHz3298380.15-16.5N1006500fcc-mpcf-2-32-40/98/38
F-35A-L100Hz - 100MHz3298381ØN2003100fcc-mpcf-2-32-40/98/38
F-37-2 Clip-On100kHz - 1GHz1281191ØSMA1003100FCC-MPCF-37-2
F-38-1 Clip-On10kHz - 200MHz554102.89SMA20110FCC-MPCF-F-38
F-38-2 Clip-On1kHz - 200MHz554101ØSMA20110FCC-MPCF-F-38
F-38-4 Clip-On1MHz - 1GHz554105.615SMA20110FCC-MPCF-F-38
F-39-110 kHz - 200 MHz188562.89SMA20110FCC-MPCF-39
F-39-21 kHz - 200 MHz188561ØSMA20110FCC-MPCF-39
F-39-41 MHz - 1 GHz188565.615SMA20110FCC-MPCF-39
F-4010 Hz - 50 MHz671531020.1-20N350100200fcc-mpcf-2-32-40/98/38
F-40-510 Hz - 50 MHz671531020.1-20N10001005000fcc-mpcf-2-67/142/53
F-421kHz - 100MHz329838615.5N35050100fcc-mpcf-2-32-40/98/38
F-42A1kHz - 100MHz327119412N502100fcc-mpcf-3-32/71/19
F-50100 kHz - 500 MHz327119919BNC*3002050fcc-mpcf-3-32/71/19
F-5110 kHz - 500 MHz3298381020N35050100fcc-mpcf-3-32/71/19
F-5210 kHz - 500 MHz40117381020N35050100fcc-mpcf-3-32-40/71/19
F-5510 kHz - 500 MHz32983810N3503100fcc-mpcf-3-32/71/19
F-52B10kHz - 400MHz4080194.513N2002100fcc-mpcf-3-32-40/71/19
F-55A1 kHz - 500 MHz3271190.1-20N35010100fcc-mpcf-3-32/71/19
F-571kHz - 500MHz4098381ØN2002100fcc-mpcf-2-32-40/98/38
F-611MHz-1GHz3271191624BNC*2002050fcc-mpcf-2/19/58/26
F-6210MHz-1GHz3271191322BNC*2002050fcc-mpcf-3-32/71/19
F-65100 kHz - 1 GHz3271191ØN3503100fcc-mpcf-3-32/71/19
F-65A10 kHz - 1 GHz3271190.1-20N35010100fcc-mpcf-3-32/71/19
F-75B1kHz - 500MHz70125381ØN2502100fcc-mpcf-2/70/125/38
F-701 kHz - 100 MHz701253810N3503100fcc-mpcf-2-70/125/38
F-7110 kHz - 500 MHz7012538818N2002550fcc-mpcf-2-70/125/38
F-72100 Hz- 100 MHz6714253514N350100100fcc-mpcf-2-67/142/53
F-72-1100 Hz- 100 MHz67142530.15-16N15012500fcc-mpcf-2-67/142/53
F-72-2100 Hz- 100 MHz67142530.01-46N70605,000fcc-mpcf-2-67/142/53
F-72-710Hz-200MHz67142530.01-44N200605,000fcc-mpcf-2-67/142/54
F-7310 Hz- 30 MHz671425326N350200200
F-7510 kHz - 500 MHz701253810N3503100fcc-mpcf-2-70/125/38
F-801 kHz - 100 MHz12719741514N350100100fcc-mpcf-1-127/197/41
F-80-11 kHz - 100 MHz1271974110N3502100fcc-mpcf-1-127/197/41
F-81100 Hz- 10 MHz1271974110N350100100fcc-mpcf-1-127/197/41
F-200010 MHz - 3 GHz1337171624SMA1001050FCC-MPCF-36 Rev B
<<<<提醒:左右滑动表格>>>>

New for 2021: F-180419-1005-1

3.2. FCC Current Monitoring Probe Calibration Fixture

<<<<提醒:左右滑动表格>>>>
Calibration Fixture ModelMatchable Current Monitoring Probe Models
F-080902-1005-2F-72-8
fcc-mpcf-1-127/197/41f-80, f-80-1, f-81
fcc-mpcf-1-32/94/64f-10, f-10-1, f-12, f-14, f-14-1, f-16, f-16-1
fcc-mpcf-2-32-40/71/19f-171221-1005-1, f-33-1, f-33-1-40mm, f-33-2, f-52b
fcc-mpcf-2-32-40/98/38f-14c, f-16b, f-16m, f-35, f-35-1, f-35a-l.

f-40, f-42, f-51, f-52, f-57

fcc-mpcf-2-67/142/53f-10a, f-10a-1, f-14a, f-14a-1, f-16a, f-16a-1.

f-170804-1005-1, f-40-5, f-72, f-72-1.

f-72-2, f-72-7, f-73

fcc-mpcf-2-70/125/38f-70, f-71, f-75
FCC-MPCF-2KF-2000
FCC-MPCF-2K Rev BF-2000-12mm
fcc-mpcf-3-32-40/71/19f-33-1-40mm, f-51a, f-51b, f-52b, f-61-40mm
fcc-mpcf-3-32/71/19f-2000-32mm-1, f-2000-32mm-2, f-33-1, f-33-2.

f-33-3, f-33-4, f-42a, f-50, f-51a, f-55, f-55a.

f-60, f-61, f-62, f-62a, f-65, f-65a

FCC-MPCF-33-5F-33-5
FCC-MPCF-36 Rev BF-36-1 Clip-On, F-36-2 Clip-On, F-36-4 Clip-On
FCC-MPCF-37-2F-37-2 Clip-On
<<<<提醒:左右滑动表格>>>>

 

3.3, FCC surface current probe

<<<<提醒:左右滑动表格>>>>
Model numberAvailable frequencyA available
internal height
B available
internal width
C
outer height
D
outer width
E
external length
ZTΩDBΩconnectorgreatest
amps
DC-60 Hz
greatest
Current <400Hz
RF
(CW)
impulse
peak value
F-32-9B100kHz-300MHz615246281213.210SMA10010010100
<<<<提醒:左右滑动表格>>>>
FCC Surface Current Probes

FCC Surface Current Probes

<<<<提醒:左右滑动表格>>>>
Model numberAvailable frequencyA
orthogonal
calibre
B
vertically
radius
C
thicknesses
(mm)
ZTΩDBΩconnectorgreatest
amps
DC-60 Hz
greatest
Current <400Hz
RF
(CW)
impulse
peak value
F-9010 kHz - 1 MHz8951380.08-22N500030010200
F-911 MHz - 100 MHz8951381.43N500030020200
F-9210 MHz - 400 MHz7644380.9-1BNC500030010200
F-961 MHZ - 450 MHz1913101.262SMA101010100
F-9710 MHz - 1.5 GHz101380.45-7SMA101010100
<<<<提醒:左右滑动表格>>>>

New in 2024

<<<<提醒:左右滑动表格>>>>
Model number3dB bandwidthRF (CW)Calibration Fixtureconnector400Hz currentpeak pulse current (physics)
F-91-13MHz - 100MHz20FCC-TEM-JM1Type-N5000200
F-92-120MHz - 400MHz10FCC-TEM-JM1Type-N5000200
F-96-110MHz - 400MHz10FCC-MPCF-96SMA10100
F-97-130MHz - 1.5GHz10FCC-MPCF-97SMA10100
<<<<提醒:左右滑动表格>>>>
EMI Current Probes - Clip-on Miniature Probes

EMI Current Probes - Clip-on Miniature Probes

 

<<<<提醒:左右滑动表格>>>>
Model numberAvailable frequencyA DiameterB
external length
C
outer width
D
outer height
ZTΩDBΩconnectorgreatest
amps
DC-60 Hz
greatest
Current <400Hz
RF
(CW)
impulse
peak value
F-36-110 kHz - 200 MHz5541319412SMA2020110
F-36-21 kHz - 200 MHz554131910SMA2020110
F-36-41 MHz - 1 GHz55413192227SMA2020110
<<<<提醒:左右滑动表格>>>>

The above is a complete catalog of FCC's current injection probes and current monitoring probes. Click on a model number to get more technical specifications, and provide the model number of the current probe to EUTTEST to get a price quote on the product.

Service

Our company sells all the instrumentation equipment products provide after-sales personnel door-to-door training or telephone, e-mail, microblogging and other ways of installation and training services.

We are committed to supplying equipment that is brand new and manufactured by the original manufacturers at home and abroad.

After-sales of the product is carried out by the after-sales policy provided by the original equipment manufacturer.

Purchase

The EUTTEST website does not sell any products online and is only used to display information about the products that our company represents and sells or researches in-house.

The prices shown are for display purposes only, please contact our sales staff to get the real-time quotation information of the required instruments and equipment products;

When you confirm your purchase, we will contact you to sign a purchase and sales contract.

Our company only deals with companies and provides formal Chinese VAT special invoices.

443 views

DISCLAIMER: Reproduction and redistribution by anyone without written permission from EUTTEST is prohibited.

If you like our products, please press Ctrl + D shortcut to favorite this product.