Introduction:
The F-170705-1005-1 is an EMI monitoring current probe manufactured by FCC (Fischer Custom Communications, Inc.) and authorized for sale by EUTTEST Shenzhen. The F-170705-1005-1 has a usable frequency range of 100 kHz to 30 MHz. a primary supply current of 750 amps DC-400 Hz and 100 amp pulses will not change the transmitted impedance.
Meets criteria:
F-170705-1005-1 May be used to test current limits on interconnecting cables 150kHz-30MHz for CISPR15-2018 as detailed in the CISPR15 standard Table 6 - Disturbance current limits at local wired ports. local wired portsother than electrical power supply interface of ELV lamps
F-170705-1005-1 can also be used to test the CISPR32 standard, contact us for more information.
Associated Products:
F-170705-1005-1 can pass a high current of 750A (DC-400Hz) and can test 67mm cable at the same time, which is expensive. (This product)
The F-170710-1005-1 can pass a current of 50A (DC-400Hz) and can simultaneously test a 32mm cable.
F-170705-1005-1 Main technical parameters:
Available frequency range: 100 kHz - 30 MHz
Internal ring diameter: 67mm
External ring diameter: 142mm
Height: 53mm;
Typical value ZtΩ(1): 2;
Typical dBΩ: 6 ;
Connector: N, 50 ohms;
Rated power current value: 750A (DC - 400 Hz);
RF (CW continuous wave): 10A;
Peak pulse current (2): 100A;
1: Calibrate the probe with a 50Ω+j0Ω load impedance.
2: Depends on pulse width and pulse repetition rate.
Calibration Fixture for F-170705-1005-1: FCC-MPCF-2/67/142/53
Transmission Impedance Graph for F-170705-1005-1