F-170329-1005-1 FCC Current Probe 10kHz - 30MHz

f-170329-1005-1 fcc
Manufacturer brand:FCC
Equipment name:Current Probe-Monitoring

Sales call:134 2515 8926

Sales mailbox:sales@euttest.com

Sales WeChat: euttest

Scan the QR code to quickly add sales WeChat:

euttest-wechat-code

F-170329-1005-1 Introduction:

The F-170329-1005-1 is an EMI monitoring current probe manufactured by FCC (Fischer Custom Communications, Inc.) and authorized for sale by EUTTEST Shenzhen. The F-170329-1005-1 has a usable frequency range of 10 kHz to 30 MHz. 1000 amps DC-400 Hz primary supply current will not change its transmission impedance.

F-170329-1005-1 Main technical parameters:

Available frequency range. 10 kHz - 30 MHz

Internal Ring Diameter. 67mm

Outer ring diameter. 142mm

Height. 53mm;

Typical value ZtΩ(1): 1.4;

Typical dBΩ. 3;

Connectors. N, 50 ohms;

额定功率电流值: 1000A (DC - 400 Hz);

RF (CW continuous wave):2A;

1: Calibrate the probe with a 50Ω+j0Ω load impedance.

 

F-170329-1005-1 Calibration Fixture:

fcc-mpcf-2/67/142/53

Transmission Impedance Graph for F-170329-1005-1

Transmission Impedance Graph for F-170329-1005-1