Introduction:
F-161012-1008-2-1 is a calibration fixture for injected current probes manufactured by FCC (Fischer Custom Communications, Inc.) and authorized to be sold by EUTTEST Shenzhen. Available frequencies 10 kHz - 10 MHz, suitable for metrological calibration of high current injection probes F-161012-1008-1 .
Most high current injection test program specifications require that an injection probe calibration fixture be part of the test equipment. This test fixture, F-161012-1008-2-1, allows the user to quickly and easily calibrate the injection probe prior to performing conformance testing. Contact us for current probe calibration instructions after purchasing this calibration fixture from EUTTEST.
F-161012-1008-2-1 The calibration fixture offers two important advantages:
1. Due to variable circuit impedance or resonance in the cable, calibration fixtures are used to build positive power into the injection probe to produce a specified current in the system under test.
2. The fixture can be used to measure the insertion loss of the injection probe.
F-161012-1008-2-1 technical parameters:
<<<<提醒:左右滑动表格>>>>Calibration Fixture Model | F-161012-1008-2-1 |
Applicable current probe type | High Current Injection Probes F-161012-1008-1 |
agent | Shenzhen EUTTEST |
frequency of use | 10 kHz - 10 MHz |
size | (L x W x H) 610 mm x 229 mm x 267 mm |
weight | 2.2kg |

VSWR for F-161012-1008-2-1