Introduction:
The F-150-1 is a BCI high current injection probe manufactured by FCC and authorized for sale by EUTTEST Shenzhen. It is designed for conducted immunity testing over a bandwidth of 2.3 GHz - 7.0 GHz. It combines high efficiency, high power rating and compact size to support single cable line testing on test benches as well as between cable bundles inside vehicles.
Product Features:
- 1, can follow the standard alternative method test methods used in ISO 11451-4 , ISO 11452-4 , MIL-STD.461 / 462 Rev D/E , FAA DO-160 Rev D/E. Only 20 watts of power is required to generate 300mA of current to a 100Ω loop impedance calibration fixture.
- 2, Broadband test. <9 dB attenuation at 2.3-7 GHz input to 100 Ω loop impedance
- 3, Maximum input power 250 watts
- 4, can accommodate EUT cables up to 12 mm in diameter.
Technical parameters:
<<<<提醒:左右滑动表格>>>>Injection Current Probe Model | F-150-1 |
manufacturer | United States FCC |
agent | Shenzhen EUTTEST |
Injection frequency range | 2.3 GHz - 7.0 GHz |
Inner ring diameter | 12 mm |
Outer ring diameter | 33 mm |
Probe Height | 13 mm |
Maximum injected power | 250 W |
insertion loss | -5dB |
Optional accessories | FCC-BCICF-150-1 Current Probe Calibration Fixture F-070430-1005-1 Current Monitoring Probe |
Insertion loss graph:

Insertion Loss Graph
FCC Manufacturer's Statement: Product specifications are subject to change without notice.